PASS/FAIL® Type 5 Integrator Steam Challenge Pack

$380.40

PASS/FAIL® Challenge Pack is a disposable test pack designed to provide a challenge to steam sterilizers at 250°F (121°C) and 273°F (134°C).

  • Disposable test pack containing a chemical integrator
  • Provides a challenge to steam sterilization loads
  • Use for load release and monitoring
SKU: 70000054 Categories: ,
Details
Price
QTY
26906200
Product: PASS/FAIL® Challenge Pack - Steam Pack with Type 5 Integrator - 20 test packs per case

Pass/Fail® Challenge Pack - Steam Pack with Type 5 Integrator - 20 test packs per Case

PASS/FAIL® Type 5 Integrator Steam Challenge Pack
$380.40
QTY
Enter quantity
Scroll to add to cart

Description

PASS/FAIL® Type 5 Integrator Steam Challenge Pack is a disposable test pack for monitoring steam sterilization cycles.

Use PASS/FAIL® in steam sterilizers at 250°F (121°C) and 273°F (134°C).

PASS/FAIL® Steam Challenge Pack contains  VAPOR LINE® Steam Sterilization Integrator. VAPOR LINE® features migrating ink which moves across the indicator into the bright green PASS area. VAPOR LINE® results correlate with the performance of a biological indicator.

VAPOR LINE® Integrator Processing
Discover why Propper Manufacturing Company’s VAPOR LINE® Type 5 Chemical Integrators is the top choice for many studios, small practices, major medical faculties, and laboratories. These integrators offer unparalleled reliability in monitoring crucial steam sterilization parameters, efficiently ensuring safe and consistent sterilization results. With user-friendly features, no training is required, making it accessible to everyone. VAPOR LINE® exceptional performance is why customers keep returning for more.

 

How to Use PASS/FAIL® Type 5 Integrator Steam Challenge Pack

      1. Place one test pack (face up) on the front, bottom shelf of a normally loaded sterilization chamber.
      2. Run a normal sterilization cycle.
      3. Upon cycle completion, remove the test pack from the sterilizer. Examine the process indicator on the top of the box to verify steam exposure. Since the test pack may be hot after sterilization, it should be disassembled only by personnel wearing proper heat protection gloves.
      4. Retrieve the sterilization record card with VAPOR LINE® integrator from within the pack.
      5. Examine the embedded VAPOR LINE® integrator for Pass or Fail results. A dark-colored bar must extend into the green (PASS) region in
        order for the result to qualify as Pass. This bar may partially or completely fill the green (PASS) area of the VAPOR LINE® window.
      6. Check the dark color bar. If it’s missing or hasn’t reached the green (PASS) region, sterilization failed. Examine cycle parameters from the sterilizer printout to identify the cause. If additional testing with a new PASS/FAIL® Pack also fails, the sterilizer may need maintenance. Don’t use the sterilizer until you resolve any functionality issues.
      7. Remove the record card from the test pack and fill in all required information. Attach the processed VAPOR LINE® integrator to this
        card and retain as part of the sterilization record.
      8. Discard the steam processed pack.